| NEW CATEGORIES FOR DUST TECHNICAL ASSESSMENT OF INDUSTRIAL VACUUM | ||||||
| CLEANERS, DUST EXTRACTORS AND SUCTION SWEEPING MACHINES | ||||||
| Formerly | SUITABLE FOR: | Since 1/97 : | ||||
| ZH 1/487, BG-Holz, TRGS 519 | EN 60335-2-69 | |||||
| IEC 60335-2-69 Annex AA | ||||||
| Category | max. | Dust | max. | |||
| penetration | Class | penetration | ||||
| value | value | |||||
| U | 5% | . Dusts with values of max. occupational | L | 1% | ||
| exposure > 1 mg/m3 | ||||||
| S | 1% | . Dusts with values of max. occupational | ||||
| exposure > 1 mg/m3 | ||||||
| G | 0 , 5 % | . Dusts with values of max. occupational | M | 0, 1 % | ||
| exposure > 0 , 1 mg/m3 | ||||||
| C | 0 , 1 % | . Dusts with values of max. occupational | ||||
| exposure > 0 , 1 mg/m3 without | ||||||
| cancerinogenic dusts ( t 35 GefStoffV ) | ||||||
| G | 0 , 5 % | . Dusts with values of max. occupational | ||||
| exposure ≤ 0 , 1 mg/m3 | ||||||
| C | 0 , 1 % | . Dusts with values of max. occupational | ||||
| exposure ≤ 0 , 1 mg/m3 and | H | 0, 005 % | ||||
| cancerinogenic dusts ( t 35 GefStoffV ) | ||||||
| K1 | 0 , 05 % | . Cancerinogenic dusts ( t 35 GefStorfV ) | ||||
| including very cancennogenic dusts | ||||||
| ( t 15 a GefStoffV ) | ||||||
| K2 | see K1 | . Dusts contaminated with pathogenes | ||||
| Additional | see K1 | . Asbestos | Additional | see H | ||
| requirements | reqirements | |||||
| for Germany | ||||||
| B1 | see | . Explodable dusts, explosion classes | B1 | see | ||
| corresponding | St1, St2 and St3 in Zone 11 | corresponding | ||||
| ( Germany ) | category | ( Germany ) | dust class | |||
| (S, G, C or K) | ( M or H ) | |||||
| H2 | 0, 2 mg (wood) | . Wood dusts | M | 0, 1% | ||
| ( Germany ) | per m3 (air) | |||||
| in Germany more than. 1200 W and/or 50 litre capacity of dust storage bin category B1 is necessary | ||||||
| The assignment of the categories G and C to the dust classes M and H depend on the limit values | ||||||
| for occupational exposure. | ||||||
| TUV PRODUCT SERVICE GMBH | Dust Classes | |||||
| Dust Laboratory | Status: 16. Dezember 1998, Rev:1 | |||||
| Mergenthalerallee 27 | Kerstin Schute | |||||
| 65760 Eschbom | print date: 1998-03-20 | |||||
| Telefon:+49 6196 9601-90; Fax: -99; E-Mail: kschute@tuvps.com | page 1 of 1 | |||||